Lepu Seal - A Professional China Mechanical Seal Manufacturer providing Cartridge Seal, Grundfos Mechanical Seal And We offer free sample!
Flushing type cooling: When the temperature of the sealing medium is between 0 and 80 t, it is usually necessary to purchase mechanical seals with flushing type cooling. The inlet of the flushing fluid is aligned with the friction surface. The purpose of flushing is to keep the temperature of the friction surface within a certain range and to prevent the accumulation of impurities near the seal face. This is a commonly used cooling method, which can be divided into self-flushing and external flushing. The inner body flushing uses the sealed medium as the flushing liquid, which can be applied to the general pump and mechanical seal equipment. A small part of the liquid is drawn from the pump outlet, directly flushes the friction end face, and then flows into the pump cavity. When conveying high temperature or medium with particles, a cooler or filter can be added to the pipeline between the pump outlet and the flushing inlet. External flushing is a separate flushing liquid system for flushing and cooling. It is mostly used to seal high temperature or particle-containing media, but its structure is more complicated. Cooling on the back of the static ring: This cooling method is to send the cooling medium (such as water) through the back of the static ring directly to the friction end face that needs to be cooled, and the cooling medium and the working medium are not mixed. This cooling method has a simple structure, good effect, and a wide range of applicable temperatures. But its disadvantage is that the hardness of cooling water is required to be low, especially the sealing of high temperature medium. Because the hardness of the water is high, scale will be generated on the shaft near the end face of the seal and the seal will fail. At the same time, it is necessary to prevent the cooling water from leaking out along the extension end of the shaft. Cooling of the outer periphery of the stationary ring: In order to solve the problem of scale, the outer periphery of the stationary ring is cooled. This method avoids the generation of scale on the shaft or the shaft sleeve because the cooling water does not directly contact the shaft or the shaft sleeve, and also prevents the water along the shaft. Axial leakage on the atmospheric side can reduce the quality of cooling water, but its cooling effect is not as good as the cooling of the back of the static ring.
Guangzhou Lepu Machinery Co., Ltd.
ADD.: No. 5, Yunkai Road, Huangpu District, Guangzhou, China
TEL.: +86-020-36158139, +86-020-36158280
Contact Person: Mr. Mark Ao
E-mail: mark@lepuseal.com;amy@lepuseal.com
FAX.: +86-020-36158281
SKYPE: lepu-seal
Whatapps: +86-18903009893