Ensure centrifugal compressor safety with this dry gas seal pre-installation testing guide. Discover static, dynamic & API 692 checks to stop toxic leaks.
Lepu Seal - A Professional China Mechanical Seal Manufacturer providing Cartridge Seal, Grundfos Mechanical Seal And We offer free sample!
mark@lepuseal.com+86 18903009893
Ensure centrifugal compressor safety with this dry gas seal pre-installation testing guide. Discover static, dynamic & API 692 checks to stop toxic leaks.
A dry gas seal is a specialized, non-contacting mechanical face seal used in high-speed centrifugal compressors. It injects clean or inert buffer gas to create a tiny physical gas barrier, just 3 to 10 microns thick, between a stationary primary ring and a rotating mating ring to prevent leaks.
Built from tough materials like silicon carbide and fluoroelastomers or perfluoroelastomers, these seals last up to 10 years. They use only 5 kW of electricity per hour, just 5% to 10% of traditional oil seal power, and reduce methane emissions by up to 97%.
Traditional oil seals leak 1 to 3 barrels of oil daily into refinery systems, damaging expensive chemical reactors and causing millions of dollars in losses. Dry gas seals run completely dry, eliminating this risk entirely.
When the machine is off, springs and pressure hold the seal faces together. As it starts spinning and passes a specific lift-off speed, bidirectional T-grooves, spiral grooves, or advanced pattern grooves on the spinning ring act as viscous micro-pumps to draw gas inward. This gas is forced over a narrow barrier or sealing dam, generating a high-pressure dynamic lifting force.
The created cushion balances against the spring pressure to maintain a stable 3–10 micron gap. This gas layer acts as a friction-free lubricant, keeping the breakaway torque low and eliminating mechanical wear.
In a standard multi-stage tandem barrier, the primary seal handles the full pressure, safely venting a controlled leak of 1 to 10 scfm. A backup seal, usually pressurized with non-reactive inert nitrogen, acts as a safety net to prevent any leaks into the outside air.
Compressors work with hazardous substances that can be toxic, corrosive, or flammable gases such as sour crude gas, hydrogen, and methane at extreme pressures up to 550 bar. Pretesting eliminates dangerous leaks and spares the costly, laborious work of having to put in a bad seal again.
Testing uncovers shipping damage like mechanical shocks or structural displacements. It also unveils defects like broken elastomeric O-rings or weak springs that cause the seal to immediately "hang up". It also establishes a static leakage rate curve to compare against the factory test certificate.
As per Sedy's historical patent, workers can test seals on-site using a portable three-piece clamp fixture. By applying ~50 psig of pressure using filtered shop air and watching the pressure decay, leaks are quickly found via audible hissing. Rapidly applying this pressure can even fix minor static seal shifts, avoiding a return trip to the manufacturer.
Before installation, dry gas seals must undergo strict testing to prove they are fit for service. While general industry guidelines like API 617 and API 692 exist, tests must strictly follow the manufacturer's exact Inspection and Test Plan (ITP).
To verify that the non-spinning seal is holding pressure, the seal is pressurized to its maximum limit, isolated, and monitored for a minimum of 30 minutes. It passes if the pressure drops by ≤ 2% and the primary seal static leakage rate is ≤ 0.5 Nm³/hr. For tandem seals, the process-side (primary) and bearing-side (secondary) seals are pressurized independently to ensure no gas leaks between them.
The shaft is spun up to its maximum continuous operating speed and trip speed. This checks the gas film stiffness and dynamic leakage, which naturally increases by 20% to 40% over static rates. The leak rate must stay ≤ 1.2 times the guaranteed value. Heat sensors like Pt100 RTDs verify that the temperature differential, or ΔT, between incoming and outgoing gas is < 15°C, proving parts aren't rubbing. Lastly, a precision machine confirms there are no abnormal vibrations < 4.5 mm/s RMS.
The seal is spun extremely fast, often over 50,000 RPM, to ensure it handles extreme centrifugal forces. This proves the silicon carbide mating rings, lock plates, and centering sleeves won't crack or shift. Afterward, the unit is slowed, emptied of pressure, and visually checked for any parts that moved out of place.
This test verifies that the separation seal, such as carbon rings or split labyrinth seals, successfully stops bearing oil from entering the main gas seal. It confirms that the usage of separation gas, like nitrogen or air, is within limits, with a static decay limit of ≤ 0.1 Nm³/hr. It also ensures the labyrinth differential pressure remains steady to keep out dirt and debris.
Before installing the seal on the pump, careful checks are needed to avoid major errors.
Compare engraved serial numbers to the manufacturer’s data sheets, ITP documents, and calibration records. Verify the secondary elastomeric seals, such as O-rings, V-rings, or metal bellows, for cracks or stiffness. Make sure these elastomers, such as FKM or FFKM, can handle the gas composition and operating temperatures (60°C to 280°C) without suffering from Rapid Gas Decompression (RGD) or explosive tearing.
Measure shaft runout using a specialized dial indicator. This Total Indicator Runout, or TIR, must be ≤ 0.05 mm to avoid vibrations. Use outside micrometers to verify the shaft perfectly matches the seal's inner bore diameter, which typically ranges from 20 mm to 350 mm. Keep proper axial and radial clearances between the rotating sleeve and stationary compressor housing to allow for dynamic thermal expansion.
Silicon carbide or tungsten carbide sealing surfaces must be completely clean of debris and skin oils. Wash them with an approved, fast-evaporating, residue-free volatile solvent. Finally, inspect the dynamic lift-off grooves, such as bidirectional T-grooves or spiral pattern grooves, under magnification to ensure no scratches or clogs stop the required gas cushion from hydrodynamic lift.
Per the API 692 standard, the gas conditioning unit must use duplex filters that capture microscopic dust down to 1 μm in size with a filtration efficiency of ≥ 99.9% (β1 ≥ 1000). Moisture must remain ≤ 10 ppm or < 0.5 ppm for critical services to stop freezing. Additionally, heaters must warm the gas 20°C to 40°C above its gas dew point line to avoid dangerous condensation.
API 692 also mandates precise measuring tools like high-accuracy flowmeters on all supply lines. Safety primary vent flow pressure transmitters must trigger a shutdown at exactly 10 times the normal gas loss or guaranteed baseline leakage volume. The primary vent line must remain unblocked to prevent reverse pressure from forcing toxic gas back inside. Lastly, test the safety blowout alarms, such as "Burst-Alerand t," continuity on the primary vent rupture disc or Pressure Relief Valve (PRV).
Under API 692, a seal gas booster must turn on when the compressor stands still or settles out to keep clean gas pushing outward through positive pressure differential. Nitrogen supply pipes must be purged to the atmosphere to clear any dirt or welding slag. Finally, per API 692 guidelines, separation seal nitrogen buffer controls must maintain sufficient differential pressure to actively block bearing oil from migrating into the dry gas seal.
The following table synthesizes the industry-standard validation requirements per API 692 and OEM specifications to ensure the seal cartridge is safe for installation and startup:
| Test Phase | Parameter Measured | Measurement Method | Certified Acceptance Limits / Tolerances | Corrective Action on Failure |
|---|---|---|---|---|
| Static Testing | Static Leakage Rate | Mass flow controller or bubble meter | Primary seal: ≤ 0.5 Nm³/hr Buffer gas: ≤ 0.1 Nm³/hr |
Inspect seal faces, clean with approved solvent, or replace O-rings |
| Static Testing | Pressure Decay Hold | Digital pressure transmitter or gauge | ≤ 2% pressure drop over a 30-minute hold | Check static O-ring seating and flange gasket material compatibility |
| Dynamic Testing | Dynamic Leakage Rate | Mass flow meter at full operating speed | ≤ 1.2 × manufacturer's guaranteed leakage (increases 20-40% over static) | Return cartridge to manufacturer for groove blockage or face contact check |
| Dynamic Testing | Vibration & Balance | High-precision radial proximity probes | Vibration amplitude < 4.5 mm/s RMS at maximum speed | Re-verify dynamic balance grades and test shaft runout |
| Dynamic Testing | Temperature Stability | Pt100 RTD / Thermocouple embedded in face | ΔT < 15°C between gas inlet and outlet streams | Increase conditioning purge flow rate; inspect for high-speed contact |
| Overspeed Verification | Rotational Velocity Tolerance | Rig tachometer/encoder | Safe and stable operation up to overspeed limits (typically ≥ 1.1 × trip speed) | Reject sleeve or mating ring components showing micro-fractures or shifts |
| Pre-Install Audits | Shaft Alignment Runout | Dial indicator on compressor rotor shaft | Total Indicator Runout (TIR) ≤ 0.05 mm | Re-machine shaft/sleeve mating or adjust bearings and coupling alignment |
| Pre-Startup GCU Check | Primary Seal Gas Filtration | Coalescing element particle rating | 1 μm spherical particle size rating with ≥ 99.9% efficiency | Replace standard undersized filters with high-capacity API 692 filters |
Pre-installation testing is not a choice, but an absolute necessity for the safety, longevity, and optimal performance of the seals in a centrifugal compressor. Dangerous gas leaks, unanticipated shutdowns of operations, and substantial equipment damage can occur from skipping pre-assembly tests. These include static, dynamic, and gas conditioning tests. Operators may rest assured that their dry gas seals will properly protect plant personnel, minimize fugitive emissions, and avoid production losses worth millions of dollars by adhering to OEM guidelines and API 692 criteria.
For reliable operations, Lepu Seal provides fully tested solutions. Every unit undergoes strict speed and pressure checks, including static, dynamic, overspeed, and leakage validation, to guarantee frictionless, non-contact performance and compliance with strict industry guidelines like API 692 standards. Contact Lepu Seal for custom designs or to upgrade using wet-to-dry seal retrofit solutions.
What is the acceptable static leakage rate for a dry gas seal?
Per standard guidelines, a non-spinning dry gas seal pressurized to its maximum limit must hold pressure during a 30-minute isolation test. The pressure decay should be ≤ 2%. For the primary seal, the static leakage rate must strictly remain ≤ 0.5 Nm³/hr to pass pre-installation checks and guarantee safety.
Why does API 692 mandate 1-micron filtration for seal gas?
Dry gas seals work on a microscopic gas cushion of 3 to 10 microns. API 692 demands high-capacity duplex filters that remove 1-micron spherical particles with an efficiency of ≥ 99.9%. Any dirt or debris that gets around the conditioning unit will inevitably clog the dynamic lift-off grooves, damaging the needed frictionless hydrodynamic lift generation.
What does a dynamic spin test verify before compressor installation?
Spinning the shaft to maximum continuous operating speed verifies critical gas film stiffness and evaluates dynamic leakage, which normally increases 20% to 40% over static baselines. This confirms leakage remains ≤ 1.2 times the guaranteed value and proves extreme centrifugal forces won’t shift the silicon carbide mating rings or induce vibrations.
Guangzhou Lepu Machinery Co., Ltd.
Add:
No. 5, Yunkai Road, Huangpu District, Guangzhou, China
Tel:
+86-020-36158139
+86-020-36158280
E-mail:
mark@lepuseal.com
Fax: +86-020-36158281
Contact Person: Mr. Mark Ao